Changelog for SimplexMotionTool PC software. Version 0.3.5 General bug fixes. Increased stability when changing target address/searching for other motors on the serial port. Improved installer. New Events page. New register file (SimplexMotionRegisters_p01.07) for future motor parameters. Version 0.3.4c Bug fixes. New register file (SimplexMotionRegisters_p01.06) for future motor parameters. Version 0.3.3 Bug fix; Events used in the setup tab when using digital target input had an error. After homing/ start/stop input activated the motor needed to get input 1-4 change to trigger the motor to start its first movement. Before In1 In2 In3 In4 Wanted speed Actual speed State 0 0 0 0 100 rpm 0 rpm After start/stop input activated 1 0 0 0 X rpm X rpm Change one of the inputs 0 0 0 0 100 rpm 100 rpm Set all to 0 again and it moves according do settings Now It will move directly after start/stop input is activated. New; Added popups to confirm that buttons are pressed in the registers tab. Added warning popup if user do not have the right parameter file in its folder. Version 0.3.2 New; "Setup" tab added. Used for simple standalone settings for Simplex Motion motors. Needs parameter version 1.05 or later to work as it uses registers 510-540 to store values. It also utilizes the event registers, so it can’t be combined with user’s own event programming.